Variable Speed Motor

Motor Speed Controller VFD Variable Frequency Drive 220V 380V Inverter 2.2kW

Motor Speed Controller VFD Variable Frequency Drive 220V 380V Inverter 2.2kW

Motor Speed Controller VFD Variable Frequency Drive 220V 380V Inverter 2.2kW    Motor Speed Controller VFD Variable Frequency Drive 220V 380V Inverter 2.2kW

VFD 220V 380V 0.75KW 1.5KW 2.2KW 3.0KW Three-phase Motor Speed Controller Frequency Converter Variable Frequency Drive Inverter. The AH280 is a robust, triple-output AC drive designed for sophisticated motor management. With a wide output frequency range of 0-400Hz, it allows for granular control over motor RPM and torque.

The unit is housed in an IP20-rated enclosure and utilizes efficient fan cooling to maintain optimal performance in temperatures ranging from -10°C to 65°C. Certified by CE, FCC, and RoHS, this drive meets international standards for quality and safety. Advanced Control Modes: Supports V/F control, Open-loop vector control, and PID Control for diverse application needs.

Comprehensive Protection: Integrated safeguards against overcurrent, overvoltage, undervoltage, module faults, overheating, short circuits, and phase defaults. Flexible Input/Output: Compatible with both single-phase and three-phase inputs, providing a stable three-phase output. Versatile I/O Interface: Includes multiple digital inputs (X1-X5) for forward/reverse, multi-speed, and jog functions, alongside switchable analog inputs (0-10V/0-20mA). Industrial Build: Features an internal memory fault check and motor parameter adjustment abnormality detection for long-term system integrity. Model Number: AH280 / AH280A.

Output Power: 0.75KW - 500KW. Output Frequency: 0 - 400Hz.

Analog Input/Output: AVI: 0-10V / ACI: 0-20mA (Switchable via jumper). Relay Output: TA/TB/TC (1 NO / 1 NC). Professional Required: All wiring work must be performed by a professional electrical engineer to ensure safety and proper configuration. Power Safety: Ensure the input power is completely off before commencing any wiring.

Grounding: Grounding terminals must be securely connected to the ground. Terminal Precautions: Do not connect the input power to the U, V, and W output terminals, as this will damage the unit. Voltage Consistency: Verify that the AC main circuit voltage matches the rated voltage of the inverter before operation. Short-Circuit Prevention: Do not connect the output wires to the shell or allow output wires to short-circuit.

External Components: If using a brake resistor, please connect according to the provided wiring diagram. Do not connect a contactor directly to the output circuit. 1 x Variable Frequency Drive (VFD). 1 x Basic Configuration Guide / Safety Sheet.


Motor Speed Controller VFD Variable Frequency Drive 220V 380V Inverter 2.2kW    Motor Speed Controller VFD Variable Frequency Drive 220V 380V Inverter 2.2kW